12 KV LBSF Panel Manufacturer in Nashik

  1. Home
  2. Locations We Serve
  3. 12 KV LBSF Panel in Nashik

EL-Tech Controls manufactures and supplies the 12 KV LBSF Panel in Nashik for distribution transformer centres, HT consumers, industrial plants, townships, hospitals and commercial buildings. Every panel is built at our Ambad MIDC, Nashik works, where we have made MV switchgear since 1995.

MSEDCL ApprovedPWD & MES ApprovedType Tested at ERDA, BarodaManufacturing Since 1995Delivery Across Nashik

Request a Quote for Nashik

12 KV LBSF Panel for Nashik's Power Distribution

Nashik is our home city. Our manufacturing works is at Ambad MIDC, so customers in Nashik get direct factory supply, quick site visits and fast after-sales support. Our panels replace the open DP structure with a safe, compact and maintenance-free switch-fuse unit, which saves space, improves safety for operators and the public, and cuts maintenance.

Our panels are approved by MSEDCL (C.E. Distribution), PWD (C.E. Electricals) and Garrison Engineers (MES), and are type-tested at ERDA, Baroda, so they are accepted for new HT connections and transformer centres under MSEDCL in Nashik. Each panel is built to suit the transformer rating and site layout, for indoor or outdoor use.

Product Details

A 12 KV LBSF (Load Break Switch Fuse) panel is a fully enclosed switching and protection unit for 11 KV distribution transformers. The non-coupled type replaces existing or new Double Pole (DP) structures at any distribution transformer centre.

Material and Construction

  • Frame made of heavy steel sheet that protects all mechanical parts from dust, insects and rain.
  • Simple, compact and tested construction that does not age or deteriorate during long periods of inactivity.
  • Epoxy resin supporting insulators that withstand the electrodynamic stresses guaranteed by the switch.
  • 100% non-porous powder coating with provision for cable entry.

Safety Mechanisms

  • Independent quick break and make operating mechanism, with springs always in the 'off' position.
  • Load break switch with fully interlocked earthing blades.
  • Interlock between LBS and door: the door cannot open while the LBS is engaged.
  • Interlock between front door and LBS: the LBS cannot be engaged while the front door is open.
  • Interlock between LBS and earth switch: the earth switch disconnects first, and only then does the LBS engage.
  • Blowing of a single HRC fuse trips the LBS immediately to prevent single phasing.

Performance

  • The arc is extinguished quickly by self-generated air through three piston cylinders, one per pole, mounted in axis with the insulators.
  • The volume of blown air and the contact separation speed ensure reliable switching even in harsh conditions.

Technical Overview

ParameterDetails
Rated voltage12 KV (for 11 KV distribution systems)
Switching device400A / 630A Load Break Switch with D.O. set / HRC fuse and earth switch
Arc quenchingSelf-generated air blast, piston cylinder per pole
InsulatorsEpoxy resin
EnclosureHeavy steel sheet, powder coated, indoor / outdoor
ApprovalsMSEDCL C.E. Distribution, PWD C.E. Electricals, Garrison Engineers (MES)
Type testingERDA, Baroda

Advantages

  • Replaces the open DP structure completely
  • Saves land compared with a DP structure
  • Safe for public areas, being fully enclosed
  • Low maintenance cost
  • Unique and compact design
  • Elegant look
  • No overhead lines required
  • Electrically safe, fully enclosed cubicle
  • Easy and smooth operation
  • Safety interlocks allow semi-skilled operation

Suitable for M.V. indoor and outdoor substations, H.T. consumers, big commercial complexes, apartments and hospitals.

Choose the Right Panel for Your Nashik Site

Panel typeBest for
12 KV LBSF PanelReplacing existing or new DP structures at any transformer centre
LBSF Coupled TypeSpace-constrained sites, basements and congested city areas
Feeder Pillar TypeTownships, hospitals and industries with more than one transformer
Feeder Pillar + CoupledMalls, business centres, IT parks and multi-townships
LBS Isolator PanelIsolation-only requirements
One I/C & Multiple O/G2 to 3 transformers at one location; a single cable saves up to 40% cost
Compact Substation11 KV HT consumers needing LBSF and metering in one IP55 enclosure

Applications in Nashik

  • Auto component and engineering units in Ambad, Satpur and Sinnar MIDC
  • Electrical and electronics manufacturers
  • Wineries, food processing and cold storages around Dindori and Niphad
  • Pharma and packaging units in Sinnar and Gonde
  • Residential townships and housing projects along Gangapur Road and Pathardi

Our Installations in Nashik

Some of the sites in Nashik where EL-Tech Controls panels are installed:

  • Mahindra Sona Ltd, Nashik
  • Lear Automotive Ltd, Nashik
  • B G Shirke (MHADA site), Nashik
  • Shreeji Complex, Nashik
  • Universal Education Trust, Nashik
  • S. M. Autovision Pvt Ltd, Sinnar

Frequently Asked Questions

Do you supply the 12 KV LBSF Panel in Nashik?

Yes. EL-Tech Controls manufactures the 12 KV LBSF Panel at Ambad MIDC in Nashik itself and supplies it directly to sites across the city and district, including Ambad MIDC, Satpur MIDC, Sinnar MIDC, Malegaon MIDC (Sinnar), Gonde and Igatpuri.

Are your panels approved for use in Nashik?

Our panels are approved by MSEDCL (C.E. Distribution), PWD (C.E. Electricals) and Garrison Engineers (MES), and are type-tested at ERDA, Baroda, so they are accepted for new HT connections and transformer centres under MSEDCL in Nashik.

What is a 12 KV LBSF Panel?

A 12 KV LBSF (Load Break Switch Fuse) panel is a fully enclosed switching and protection unit for 11 KV distribution transformers. The non-coupled type replaces existing or new Double Pole (DP) structures at any distribution transformer centre.

Why replace a DP structure with an LBSF panel?

An LBSF panel is fully enclosed and interlocked, so it is safer for operators and the public, needs less land, has no overhead lines and costs less to maintain than an open DP structure.

Is the 12 KV LBSF Panel suitable for heavy monsoon rain in Nashik?

Yes. The heavy steel sheet enclosure protects the mechanism from rain, dust and insects, which matters during Nashik's heavy monsoon.

How do I get a quotation for the 12 KV LBSF Panel in Nashik?

Call +91 98220 21564, email response@eltechcontrols.com or fill in the enquiry form with your transformer rating, number of transformers and site location in Nashik.

Areas We Serve in Nashik

  • Ambad MIDC
  • Satpur MIDC
  • Sinnar MIDC
  • Malegaon MIDC (Sinnar)
  • Gonde
  • Igatpuri
  • Dindori
  • Vilholi
  • Nashik Road
  • Deolali
  • Pathardi
  • Gangapur Road
  • Ozar
  • Niphad
  • Malegaon

Why EL-Tech Controls

  • Over two decades of LBSF panel manufacturing
  • Easy and smooth operation, no overhead lines
  • Fully enclosed, electrically safe cubicle
  • Safety interlocks allow semi-skilled operation
  • Less space and low maintenance cost
  • Direct manufacturer supply to Nashik

Contact for Nashik Enquiries

+91 98220 21564
+91 253 2383478 / 2380076
response@eltechcontrols.com
A-9/4/3, MIDC, Ambad, Nashik 422010

Need a 12 KV LBSF Panel in Nashik?

Share your transformer rating, quantity and site location for a quick quotation.

Send Enquiry