EL-Tech Controls manufactures and supplies the LBSF Coupled Type Panel in Nashik for distribution transformer centres, HT consumers, industrial plants, townships, hospitals and commercial buildings. Every panel is built at our Ambad MIDC, Nashik works, where we have made MV switchgear since 1995.




LBSF Coupled Type Panel for Nashik's Power Distribution
Nashik is our home city. Our manufacturing works is at Ambad MIDC, so customers in Nashik get direct factory supply, quick site visits and fast after-sales support. Because the panel sits directly against the transformer, it removes the 11 KV cable run between them, which is a real advantage on tight plots, basements and congested city areas.
Our panels are approved by MSEDCL (C.E. Distribution), PWD (C.E. Electricals) and Garrison Engineers (MES), and are type-tested at ERDA, Baroda, so they are accepted for new HT connections and transformer centres under MSEDCL in Nashik. Each panel is built to suit the transformer rating and site layout, for indoor or outdoor use.
Product Details
The coupled LBSF is an upgraded version of the LBSF panel for places with space constraints. The panel is coupled to a compatible transformer through a fabricated bus duct with sleeved copper bus bars, connected directly to the H.V. side bushing of the transformer. Special care is taken to avoid oil leakage at the bushing.
Material and Construction
- Frame made of heavy steel sheet that protects all mechanical parts from dust, insects and rain.
- Simple, compact and tested construction that does not age or deteriorate during long periods of inactivity.
- Epoxy resin supporting insulators that withstand the electrodynamic stresses guaranteed by the switch.
- 100% non-porous powder coating with provision for cable entry.
Safety Mechanisms
- Independent quick break and make operating mechanism, with springs always in the 'off' position.
- Load break switch with fully interlocked earthing blades.
- Interlock between LBS and door: the door cannot open while the LBS is engaged.
- Interlock between front door and LBS: the LBS cannot be engaged while the front door is open.
- Interlock between LBS and earth switch: the earth switch disconnects first, and only then does the LBS engage.
- Blowing of a single HRC fuse trips the LBS immediately to prevent single phasing.
Performance
- The arc is extinguished quickly by self-generated air through three piston cylinders, one per pole, mounted in axis with the insulators.
- The volume of blown air and the contact separation speed ensure reliable switching even in harsh conditions.
Technical Overview
| Parameter | Details |
|---|---|
| Rated voltage | 12 KV (for 11 KV distribution systems) |
| Switching device | 400A / 630A Load Break Switch with D.O. set / HRC fuse and earth switch |
| Transformer connection | Fabricated bus duct with sleeved copper bus bars to the H.V. bushing |
| Insulators | Epoxy resin |
| Enclosure | Heavy steel sheet, powder coated, indoor / outdoor |
| Approvals | MSEDCL C.E. Distribution, PWD C.E. Electricals, Garrison Engineers (MES) |
| Type testing | ERDA, Baroda |
Advantages
- Reduces 11 KV XLPE cable
- Reduces the number of 11 KV jointing kits
- Low maintenance cost
- Uses minimum land area
- Unique and compact design
- Elegant look
- No overhead lines required
- Electrically safe, fully enclosed cubicle
- Easy and smooth operation
- Safety interlocks allow semi-skilled operation
Suitable for industry, apartments, malls and congested areas in a city.
Choose the Right Panel for Your Nashik Site
| Panel type | Best for |
|---|---|
| 12 KV LBSF Panel | Replacing existing or new DP structures at any transformer centre |
| LBSF Coupled Type | Space-constrained sites, basements and congested city areas |
| Feeder Pillar Type | Townships, hospitals and industries with more than one transformer |
| Feeder Pillar + Coupled | Malls, business centres, IT parks and multi-townships |
| LBS Isolator Panel | Isolation-only requirements |
| One I/C & Multiple O/G | 2 to 3 transformers at one location; a single cable saves up to 40% cost |
| Compact Substation | 11 KV HT consumers needing LBSF and metering in one IP55 enclosure |
Applications in Nashik
- Auto component and engineering units in Ambad, Satpur and Sinnar MIDC
- Electrical and electronics manufacturers
- Wineries, food processing and cold storages around Dindori and Niphad
- Pharma and packaging units in Sinnar and Gonde
- Residential townships and housing projects along Gangapur Road and Pathardi
Our Installations in Nashik
Some of the sites in Nashik where EL-Tech Controls panels are installed:
- Mahindra Sona Ltd, Nashik
- Lear Automotive Ltd, Nashik
- B G Shirke (MHADA site), Nashik
- Shreeji Complex, Nashik
- Universal Education Trust, Nashik
- S. M. Autovision Pvt Ltd, Sinnar
Frequently Asked Questions
Do you supply the LBSF Coupled Type Panel in Nashik?
Yes. EL-Tech Controls manufactures the LBSF Coupled Type Panel at Ambad MIDC in Nashik itself and supplies it directly to sites across the city and district, including Ambad MIDC, Satpur MIDC, Sinnar MIDC, Malegaon MIDC (Sinnar), Gonde and Igatpuri.
Are your panels approved for use in Nashik?
Our panels are approved by MSEDCL (C.E. Distribution), PWD (C.E. Electricals) and Garrison Engineers (MES), and are type-tested at ERDA, Baroda, so they are accepted for new HT connections and transformer centres under MSEDCL in Nashik.
What is a LBSF Coupled Type Panel?
The coupled LBSF is an upgraded version of the LBSF panel for places with space constraints. The panel is coupled to a compatible transformer through a fabricated bus duct with sleeved copper bus bars, connected directly to the H.V. side bushing of the transformer. Special care is taken to avoid oil leakage at the bushing.
What is the advantage of a coupled type LBSF panel?
It connects directly to the transformer through a bus duct, so you save 11 KV XLPE cable and jointing kits, use less land and reduce maintenance.
Is the LBSF Coupled Type Panel suitable for heavy monsoon rain in Nashik?
Yes. The heavy steel sheet enclosure protects the mechanism from rain, dust and insects, which matters during Nashik's heavy monsoon.
How do I get a quotation for the LBSF Coupled Type Panel in Nashik?
Call +91 98220 21564, email response@eltechcontrols.com or fill in the enquiry form with your transformer rating, number of transformers and site location in Nashik.
Areas We Serve in Nashik
- Ambad MIDC
- Satpur MIDC
- Sinnar MIDC
- Malegaon MIDC (Sinnar)
- Gonde
- Igatpuri
- Dindori
- Vilholi
- Nashik Road
- Deolali
- Pathardi
- Gangapur Road
- Ozar
- Niphad
- Malegaon
Why EL-Tech Controls
- Over two decades of LBSF panel manufacturing
- Easy and smooth operation, no overhead lines
- Fully enclosed, electrically safe cubicle
- Safety interlocks allow semi-skilled operation
- Less space and low maintenance cost
- Direct manufacturer supply to Nashik
Contact for Nashik Enquiries
+91 98220 21564
+91 253 2383478 / 2380076
response@eltechcontrols.com
A-9/4/3, MIDC, Ambad, Nashik 422010
Need a LBSF Coupled Type Panel in Nashik?
Share your transformer rating, quantity and site location for a quick quotation.
Send EnquiryOther Products in Nashik
- 12 KV LBSF Panel in Nashik
- Feeder Pillar Type in Nashik
- Feeder Pillar + Coupled in Nashik
- LBS Isolator Panel in Nashik
- One I/C & Multiple O/G in Nashik
- Compact Substation in Nashik
- Panel Cleaning Solutions in Nashik
LBSF Coupled Type Panel in Nearby Cities
See full product details on our 12 KV LBSF Panel - Coupled Type page, or view all locations we serve.