12 KV Compact Substation (CSS) Manufacturer in Raigad

  1. Home
  2. Locations We Serve
  3. 12 KV Compact Substation in Raigad

EL-Tech Controls manufactures and supplies the 12 KV Compact Substation in Raigad for distribution transformer centres, HT consumers, industrial plants, townships, hospitals and commercial buildings. Every panel is built at our Ambad MIDC, Nashik works, where we have made MV switchgear since 1995.

MSEDCL ApprovedPWD & MES ApprovedType Tested at ERDA, BarodaManufacturing Since 1995Delivery Across Raigad

Request a Quote for Raigad

12 KV Compact Substation for Raigad's Power Distribution

Raigad district runs from Panvel and Taloja down to Roha and Mahad, one of Maharashtra's main chemical and process industry corridors, with large logistics activity around Uran and JNPA. All components are housed in one enclosure with separate I/C and O/G compartments, natural ventilation and IP55 protection (IEC 60529), with doors fitted with double-point closing and flush handles for padlocking.

Our panels are approved by MSEDCL (C.E. Distribution), PWD (C.E. Electricals) and Garrison Engineers (MES), and are type-tested at ERDA, Baroda, so they are accepted for new HT connections and transformer centres under MSEDCL in Raigad. Each panel is built to suit the transformer rating and site layout, for indoor or outdoor use.

Product Details

The compact substation is designed for personnel safety where H.T. equipment is located in populated areas. It is designed and tested in accordance with IEC 62271-200 and contains a metering kiosk (CT and PT) and a medium voltage load break switch, suitable for all 11 KV H.T. consumers.

Material and Construction

  • Frame made of heavy steel sheet that protects all mechanical parts from dust, insects and rain.
  • Simple, compact and tested construction that does not age or deteriorate during long periods of inactivity.
  • Epoxy resin supporting insulators that withstand the electrodynamic stresses guaranteed by the switch.
  • 100% non-porous powder coating with provision for cable entry.

Safety Mechanisms

  • Independent quick break and make operating mechanism, with springs always in the 'off' position.
  • Load break switch with fully interlocked earthing blades.
  • Interlock between LBS and door: the door cannot open while the LBS is engaged.
  • Interlock between front door and LBS: the LBS cannot be engaged while the front door is open.
  • Interlock between LBS and earth switch: the earth switch disconnects first, and only then does the LBS engage.
  • Blowing of a single HRC fuse trips the LBS immediately to prevent single phasing.

Performance

  • The arc is extinguished quickly by self-generated air through three piston cylinders, one per pole, mounted in axis with the insulators.
  • The volume of blown air and the contact separation speed ensure reliable switching even in harsh conditions.

Technical Overview

ParameterDetails
Rated voltage12 KV (for 11 KV distribution systems)
Design standardIEC 62271-200
Degree of protectionIP55 as per IEC 60529
MeteringCT and PT metering kiosk
CompartmentsSeparate I/C and O/G compartments, natural ventilation
InsulatorsEpoxy resin
EnclosureHeavy steel sheet, powder coated, indoor / outdoor
ApprovalsMSEDCL C.E. Distribution, PWD C.E. Electricals, Garrison Engineers (MES)
Type testingERDA, Baroda

Advantages

  • Elegant and compact design
  • Uses minimum land area
  • Reduces cable length
  • Requires fewer jointing kits
  • Maintenance free
  • Easy and smooth operation
  • Safety interlocks
  • Unique and compact design
  • Elegant look
  • Low maintenance cost
  • No overhead lines required
  • Electrically safe, fully enclosed cubicle
  • Safety interlocks allow semi-skilled operation

Suitable for rooftops, basements and portable construction sites. It is easy to install and can be mounted on skid frames, channels with lifting hooks or portable trolleys.

Choose the Right Panel for Your Raigad Site

Panel typeBest for
12 KV LBSF PanelReplacing existing or new DP structures at any transformer centre
LBSF Coupled TypeSpace-constrained sites, basements and congested city areas
Feeder Pillar TypeTownships, hospitals and industries with more than one transformer
Feeder Pillar + CoupledMalls, business centres, IT parks and multi-townships
LBS Isolator PanelIsolation-only requirements
One I/C & Multiple O/G2 to 3 transformers at one location; a single cable saves up to 40% cost
Compact Substation11 KV HT consumers needing LBSF and metering in one IP55 enclosure

Applications in Raigad

  • Chemical and petrochemical units in Roha, Mahad and Nagothane
  • Engineering and pharma units in Patalganga and Taloja
  • Port and logistics facilities around Uran and JNPA
  • Steel and industrial units in Khopoli
  • Resorts, housing and township projects in Karjat, Alibag and Panvel

Frequently Asked Questions

Do you supply the 12 KV Compact Substation in Raigad?

Yes. EL-Tech Controls manufactures the 12 KV Compact Substation at its Ambad MIDC, Nashik works and supplies it to sites across Raigad, including Panvel, Taloja, Patalganga MIDC, Rasayani, Khopoli and Roha MIDC.

Are your panels approved for use in Raigad?

Our panels are approved by MSEDCL (C.E. Distribution), PWD (C.E. Electricals) and Garrison Engineers (MES), and are type-tested at ERDA, Baroda, so they are accepted for new HT connections and transformer centres under MSEDCL in Raigad.

What is a 12 KV Compact Substation?

The compact substation is designed for personnel safety where H.T. equipment is located in populated areas. It is designed and tested in accordance with IEC 62271-200 and contains a metering kiosk (CT and PT) and a medium voltage load break switch, suitable for all 11 KV H.T. consumers.

What does an EL-Tech compact substation include?

It combines a medium voltage load break switch, a CT and PT metering kiosk and separate I/C and O/G compartments in one IP55 enclosure, designed to IEC 62271-200.

Is the 12 KV Compact Substation suitable for humid, salt-laden coastal air in Raigad?

Yes. The fully enclosed heavy steel sheet body and powder coating protect the mechanism from rain, dust and the humid coastal air of Raigad.

How do I get a quotation for the 12 KV Compact Substation in Raigad?

Call +91 98220 21564, email response@eltechcontrols.com or fill in the enquiry form with your transformer rating, number of transformers and site location in Raigad.

Areas We Serve in Raigad

  • Panvel
  • Taloja
  • Patalganga MIDC
  • Rasayani
  • Khopoli
  • Roha MIDC
  • Mahad MIDC
  • Nagothane
  • Alibag
  • Pen
  • Uran
  • Karjat

Why EL-Tech Controls

  • Over two decades of LBSF panel manufacturing
  • Easy and smooth operation, no overhead lines
  • Fully enclosed, electrically safe cubicle
  • Safety interlocks allow semi-skilled operation
  • Less space and low maintenance cost
  • Direct manufacturer supply to Raigad

Contact for Raigad Enquiries

+91 98220 21564
+91 253 2383478 / 2380076
response@eltechcontrols.com
A-9/4/3, MIDC, Ambad, Nashik 422010

Need a 12 KV Compact Substation in Raigad?

Share your transformer rating, quantity and site location for a quick quotation.

Send Enquiry