EL-Tech Controls manufactures and supplies the 12 KV LBSF Panel in Amravati for distribution transformer centres, HT consumers, industrial plants, townships, hospitals and commercial buildings. Every panel is built at our Ambad MIDC, Nashik works, where we have made MV switchgear since 1995.




12 KV LBSF Panel for Amravati's Power Distribution
Amravati is building a major textile base around Nandgaonpeth, while the region's cotton, ginning and agro-processing units continue to expand. Our panels replace the open DP structure with a safe, compact and maintenance-free switch-fuse unit, which saves space, improves safety for operators and the public, and cuts maintenance.
Our panels are approved by MSEDCL (C.E. Distribution), PWD (C.E. Electricals) and Garrison Engineers (MES), and are type-tested at ERDA, Baroda, so they are accepted for new HT connections and transformer centres under MSEDCL in Amravati. Each panel is built to suit the transformer rating and site layout, for indoor or outdoor use.
Product Details
A 12 KV LBSF (Load Break Switch Fuse) panel is a fully enclosed switching and protection unit for 11 KV distribution transformers. The non-coupled type replaces existing or new Double Pole (DP) structures at any distribution transformer centre.
Material and Construction
- Frame made of heavy steel sheet that protects all mechanical parts from dust, insects and rain.
- Simple, compact and tested construction that does not age or deteriorate during long periods of inactivity.
- Epoxy resin supporting insulators that withstand the electrodynamic stresses guaranteed by the switch.
- 100% non-porous powder coating with provision for cable entry.
Safety Mechanisms
- Independent quick break and make operating mechanism, with springs always in the 'off' position.
- Load break switch with fully interlocked earthing blades.
- Interlock between LBS and door: the door cannot open while the LBS is engaged.
- Interlock between front door and LBS: the LBS cannot be engaged while the front door is open.
- Interlock between LBS and earth switch: the earth switch disconnects first, and only then does the LBS engage.
- Blowing of a single HRC fuse trips the LBS immediately to prevent single phasing.
Performance
- The arc is extinguished quickly by self-generated air through three piston cylinders, one per pole, mounted in axis with the insulators.
- The volume of blown air and the contact separation speed ensure reliable switching even in harsh conditions.
Technical Overview
| Parameter | Details |
|---|---|
| Rated voltage | 12 KV (for 11 KV distribution systems) |
| Switching device | 400A / 630A Load Break Switch with D.O. set / HRC fuse and earth switch |
| Arc quenching | Self-generated air blast, piston cylinder per pole |
| Insulators | Epoxy resin |
| Enclosure | Heavy steel sheet, powder coated, indoor / outdoor |
| Approvals | MSEDCL C.E. Distribution, PWD C.E. Electricals, Garrison Engineers (MES) |
| Type testing | ERDA, Baroda |
Advantages
- Replaces the open DP structure completely
- Saves land compared with a DP structure
- Safe for public areas, being fully enclosed
- Low maintenance cost
- Unique and compact design
- Elegant look
- No overhead lines required
- Electrically safe, fully enclosed cubicle
- Easy and smooth operation
- Safety interlocks allow semi-skilled operation
Suitable for M.V. indoor and outdoor substations, H.T. consumers, big commercial complexes, apartments and hospitals.
Choose the Right Panel for Your Amravati Site
| Panel type | Best for |
|---|---|
| 12 KV LBSF Panel | Replacing existing or new DP structures at any transformer centre |
| LBSF Coupled Type | Space-constrained sites, basements and congested city areas |
| Feeder Pillar Type | Townships, hospitals and industries with more than one transformer |
| Feeder Pillar + Coupled | Malls, business centres, IT parks and multi-townships |
| LBS Isolator Panel | Isolation-only requirements |
| One I/C & Multiple O/G | 2 to 3 transformers at one location; a single cable saves up to 40% cost |
| Compact Substation | 11 KV HT consumers needing LBSF and metering in one IP55 enclosure |
Applications in Amravati
- Textile and apparel units in Nandgaonpeth
- Cotton ginning and pressing units
- Agro and orange processing units around Warud and Morshi
- Hospitals and educational institutes
- Commercial and residential projects
Frequently Asked Questions
Do you supply the 12 KV LBSF Panel in Amravati?
Yes. EL-Tech Controls manufactures the 12 KV LBSF Panel at its Ambad MIDC, Nashik works and supplies it to sites across Amravati, including Amravati MIDC, Nandgaonpeth MIDC, Badnera, Achalpur, Morshi and Warud.
Are your panels approved for use in Amravati?
Our panels are approved by MSEDCL (C.E. Distribution), PWD (C.E. Electricals) and Garrison Engineers (MES), and are type-tested at ERDA, Baroda, so they are accepted for new HT connections and transformer centres under MSEDCL in Amravati.
What is a 12 KV LBSF Panel?
A 12 KV LBSF (Load Break Switch Fuse) panel is a fully enclosed switching and protection unit for 11 KV distribution transformers. The non-coupled type replaces existing or new Double Pole (DP) structures at any distribution transformer centre.
Why replace a DP structure with an LBSF panel?
An LBSF panel is fully enclosed and interlocked, so it is safer for operators and the public, needs less land, has no overhead lines and costs less to maintain than an open DP structure.
Is the 12 KV LBSF Panel suitable for high summer temperatures and dust in Amravati?
Yes. The fully enclosed heavy steel sheet body keeps out dust and insects, and the simple mechanism stays reliable through Amravati's hot, dusty summers.
How do I get a quotation for the 12 KV LBSF Panel in Amravati?
Call +91 98220 21564, email response@eltechcontrols.com or fill in the enquiry form with your transformer rating, number of transformers and site location in Amravati.
Areas We Serve in Amravati
- Amravati MIDC
- Nandgaonpeth MIDC
- Badnera
- Achalpur
- Morshi
- Warud
- Daryapur
- Chandur Railway
Why EL-Tech Controls
- Over two decades of LBSF panel manufacturing
- Easy and smooth operation, no overhead lines
- Fully enclosed, electrically safe cubicle
- Safety interlocks allow semi-skilled operation
- Less space and low maintenance cost
- Direct manufacturer supply to Amravati
Contact for Amravati Enquiries
+91 98220 21564
+91 253 2383478 / 2380076
response@eltechcontrols.com
A-9/4/3, MIDC, Ambad, Nashik 422010
Need a 12 KV LBSF Panel in Amravati?
Share your transformer rating, quantity and site location for a quick quotation.
Send EnquiryOther Products in Amravati
- LBSF Coupled Type in Amravati
- Feeder Pillar Type in Amravati
- Feeder Pillar + Coupled in Amravati
- LBS Isolator Panel in Amravati
- One I/C & Multiple O/G in Amravati
- Compact Substation in Amravati
- Panel Cleaning Solutions in Amravati
12 KV LBSF Panel in Nearby Cities
See full product details on our 12 KV LBSF Panel page, or view all locations we serve.
