12 KV LBSF One Incomer & Multiple Outgoing Panel in Surat

  1. Home
  2. Locations We Serve
  3. LBSF One I/C & Multiple O/G Panel in Surat

EL-Tech Controls manufactures and supplies the LBSF One I/C & Multiple O/G Panel in Surat for distribution transformer centres, HT consumers, industrial plants, townships, hospitals and commercial buildings. Every panel is built at our Ambad MIDC, Nashik works, where we have made MV switchgear since 1995.

MSEDCL ApprovedPWD & MES ApprovedType Tested at ERDA, BarodaManufacturing Since 1995Delivery Across Surat

Request a Quote for Surat

LBSF One I/C & Multiple O/G Panel for Surat's Power Distribution

Surat is one of India's fastest growing cities, known for diamonds and textiles, with heavy industry at Hazira and large estates at Sachin and Pandesara GIDC. One incomer feeding several outgoing LBSF units in one line-up keeps the substation compact and cuts cable length, jointing kits and civil work.

In Surat, power is distributed by Torrent Power and DGVCL. Our panels are approved by MSEDCL (C.E. Distribution), PWD (C.E. Electricals) and Garrison Engineers (MES), and are type-tested at ERDA, Baroda. Share your utility or consultant specification and we will confirm compliance before manufacturing. Each panel is built to suit the transformer rating and site layout, for indoor or outdoor use.

Product Details

This segment is useful where 2 or 3 distribution transformers are located in one place. A single cable can be laid for the whole setup, saving costs by up to 40%. A breaker can be installed before this unit as per the I.E. rules and coupled to the panel through an adaptor panel.

Material and Construction

  • Frame made of heavy steel sheet that protects all mechanical parts from dust, insects and rain.
  • Simple, compact and tested construction that does not age or deteriorate during long periods of inactivity.
  • Epoxy resin supporting insulators that withstand the electrodynamic stresses guaranteed by the switch.
  • 100% non-porous powder coating with provision for cable entry.

Safety Mechanisms

  • Independent quick break and make operating mechanism, with springs always in the 'off' position.
  • Load break switch with fully interlocked earthing blades.
  • Interlock between LBS and door: the door cannot open while the LBS is engaged.
  • Interlock between front door and LBS: the LBS cannot be engaged while the front door is open.
  • Interlock between LBS and earth switch: the earth switch disconnects first, and only then does the LBS engage.
  • Blowing of a single HRC fuse trips the LBS immediately to prevent single phasing.

Performance

  • The arc is extinguished quickly by self-generated air through three piston cylinders, one per pole, mounted in axis with the insulators.
  • The volume of blown air and the contact separation speed ensure reliable switching even in harsh conditions.

Technical Overview

ParameterDetails
Rated voltage12 KV (for 11 KV distribution systems)
Switching device400A / 630A Load Break Switch with HRC fuse and earth switch on each outgoing
ConfigurationOne incomer with 2 or 3 outgoing feeders
InsulatorsEpoxy resin
EnclosureHeavy steel sheet, powder coated, indoor / outdoor
ApprovalsMSEDCL C.E. Distribution, PWD C.E. Electricals, Garrison Engineers (MES)
Type testingERDA, Baroda

Advantages

  • Uses minimum land area
  • Reduces cable length
  • Maintenance free
  • Cost saving of up to 40% on cabling
  • Unique and compact design
  • Elegant look
  • Low maintenance cost
  • No overhead lines required
  • Electrically safe, fully enclosed cubicle
  • Easy and smooth operation
  • Safety interlocks allow semi-skilled operation

Suitable for townships, multi-speciality hospitals and commercial complexes.

Choose the Right Panel for Your Surat Site

Panel typeBest for
12 KV LBSF PanelReplacing existing or new DP structures at any transformer centre
LBSF Coupled TypeSpace-constrained sites, basements and congested city areas
Feeder Pillar TypeTownships, hospitals and industries with more than one transformer
Feeder Pillar + CoupledMalls, business centres, IT parks and multi-townships
LBS Isolator PanelIsolation-only requirements
One I/C & Multiple O/G2 to 3 transformers at one location; a single cable saves up to 40% cost
Compact Substation11 KV HT consumers needing LBSF and metering in one IP55 enclosure

Applications in Surat

  • Steel, petrochemical and engineering plants at Hazira
  • Textile processing units in Sachin and Pandesara GIDC
  • Diamond processing units and commercial complexes
  • Warehousing along the Mumbai-Ahmedabad highway
  • Residential and township projects

Frequently Asked Questions

Do you supply the LBSF One I/C & Multiple O/G Panel in Surat?

Yes. EL-Tech Controls manufactures the LBSF One I/C & Multiple O/G Panel at its Ambad MIDC, Nashik works and supplies it to sites across Surat, including Hazira, Sachin GIDC, Pandesara GIDC, Udhna, Kim and Palsana.

Are your panels approved for use in Surat?

In Surat, power is distributed by Torrent Power and DGVCL. Our panels are approved by MSEDCL (C.E. Distribution), PWD (C.E. Electricals) and Garrison Engineers (MES), and are type-tested at ERDA, Baroda. Share your utility or consultant specification and we will confirm compliance before manufacturing.

What is a LBSF One I/C & Multiple O/G Panel?

This segment is useful where 2 or 3 distribution transformers are located in one place. A single cable can be laid for the whole setup, saving costs by up to 40%. A breaker can be installed before this unit as per the I.E. rules and coupled to the panel through an adaptor panel.

How many transformers can one I/C & multiple O/G panel feed?

It is typically built for 2 or 3 distribution transformers at one location, all fed through a single incoming cable.

Is the LBSF One I/C & Multiple O/G Panel suitable for humid, salt-laden coastal air in Surat?

Yes. The fully enclosed heavy steel sheet body and powder coating protect the mechanism from rain, dust and the humid coastal air of Surat.

How do I get a quotation for the LBSF One I/C & Multiple O/G Panel in Surat?

Call +91 98220 21564, email response@eltechcontrols.com or fill in the enquiry form with your transformer rating, number of transformers and site location in Surat.

Areas We Serve in Surat

  • Hazira
  • Sachin GIDC
  • Pandesara GIDC
  • Udhna
  • Kim
  • Palsana
  • Kadodara
  • Olpad
  • Pipodara
  • Bardoli

Why EL-Tech Controls

  • Over two decades of LBSF panel manufacturing
  • Easy and smooth operation, no overhead lines
  • Fully enclosed, electrically safe cubicle
  • Safety interlocks allow semi-skilled operation
  • Less space and low maintenance cost
  • Direct manufacturer supply to Surat

Contact for Surat Enquiries

+91 98220 21564
+91 253 2383478 / 2380076
response@eltechcontrols.com
A-9/4/3, MIDC, Ambad, Nashik 422010

Need a LBSF One I/C & Multiple O/G Panel in Surat?

Share your transformer rating, quantity and site location for a quick quotation.

Send Enquiry