EL-Tech Controls manufactures and supplies the LBSF One I/C & Multiple O/G Panel in Kolhapur for distribution transformer centres, HT consumers, industrial plants, townships, hospitals and commercial buildings. Every panel is built at our Ambad MIDC, Nashik works, where we have made MV switchgear since 1995.




LBSF One I/C & Multiple O/G Panel for Kolhapur's Power Distribution
Kolhapur is one of India's leading foundry and engineering clusters, with Shiroli, Gokul Shirgaon and Kagal MIDC, plus the textile hub of Ichalkaranji close by. One incomer feeding several outgoing LBSF units in one line-up keeps the substation compact and cuts cable length, jointing kits and civil work.
Our panels are approved by MSEDCL (C.E. Distribution), PWD (C.E. Electricals) and Garrison Engineers (MES), and are type-tested at ERDA, Baroda, so they are accepted for new HT connections and transformer centres under MSEDCL in Kolhapur. Each panel is built to suit the transformer rating and site layout, for indoor or outdoor use.
Product Details
This segment is useful where 2 or 3 distribution transformers are located in one place. A single cable can be laid for the whole setup, saving costs by up to 40%. A breaker can be installed before this unit as per the I.E. rules and coupled to the panel through an adaptor panel.
Material and Construction
- Frame made of heavy steel sheet that protects all mechanical parts from dust, insects and rain.
- Simple, compact and tested construction that does not age or deteriorate during long periods of inactivity.
- Epoxy resin supporting insulators that withstand the electrodynamic stresses guaranteed by the switch.
- 100% non-porous powder coating with provision for cable entry.
Safety Mechanisms
- Independent quick break and make operating mechanism, with springs always in the 'off' position.
- Load break switch with fully interlocked earthing blades.
- Interlock between LBS and door: the door cannot open while the LBS is engaged.
- Interlock between front door and LBS: the LBS cannot be engaged while the front door is open.
- Interlock between LBS and earth switch: the earth switch disconnects first, and only then does the LBS engage.
- Blowing of a single HRC fuse trips the LBS immediately to prevent single phasing.
Performance
- The arc is extinguished quickly by self-generated air through three piston cylinders, one per pole, mounted in axis with the insulators.
- The volume of blown air and the contact separation speed ensure reliable switching even in harsh conditions.
Technical Overview
| Parameter | Details |
|---|---|
| Rated voltage | 12 KV (for 11 KV distribution systems) |
| Switching device | 400A / 630A Load Break Switch with HRC fuse and earth switch on each outgoing |
| Configuration | One incomer with 2 or 3 outgoing feeders |
| Insulators | Epoxy resin |
| Enclosure | Heavy steel sheet, powder coated, indoor / outdoor |
| Approvals | MSEDCL C.E. Distribution, PWD C.E. Electricals, Garrison Engineers (MES) |
| Type testing | ERDA, Baroda |
Advantages
- Uses minimum land area
- Reduces cable length
- Maintenance free
- Cost saving of up to 40% on cabling
- Unique and compact design
- Elegant look
- Low maintenance cost
- No overhead lines required
- Electrically safe, fully enclosed cubicle
- Easy and smooth operation
- Safety interlocks allow semi-skilled operation
Suitable for townships, multi-speciality hospitals and commercial complexes.
Choose the Right Panel for Your Kolhapur Site
| Panel type | Best for |
|---|---|
| 12 KV LBSF Panel | Replacing existing or new DP structures at any transformer centre |
| LBSF Coupled Type | Space-constrained sites, basements and congested city areas |
| Feeder Pillar Type | Townships, hospitals and industries with more than one transformer |
| Feeder Pillar + Coupled | Malls, business centres, IT parks and multi-townships |
| LBS Isolator Panel | Isolation-only requirements |
| One I/C & Multiple O/G | 2 to 3 transformers at one location; a single cable saves up to 40% cost |
| Compact Substation | 11 KV HT consumers needing LBSF and metering in one IP55 enclosure |
Applications in Kolhapur
- Foundries and engineering units in Shiroli and Gokul Shirgaon MIDC
- Textile and powerloom units in Ichalkaranji
- Sugar factories and dairies
- Hospitals, hotels and commercial complexes
- Residential and township projects
Frequently Asked Questions
Do you supply the LBSF One I/C & Multiple O/G Panel in Kolhapur?
Yes. EL-Tech Controls manufactures the LBSF One I/C & Multiple O/G Panel at its Ambad MIDC, Nashik works and supplies it to sites across Kolhapur, including Shiroli MIDC, Gokul Shirgaon MIDC, Kagal MIDC, Ichalkaranji, Jaysingpur and Hatkanangale.
Are your panels approved for use in Kolhapur?
Our panels are approved by MSEDCL (C.E. Distribution), PWD (C.E. Electricals) and Garrison Engineers (MES), and are type-tested at ERDA, Baroda, so they are accepted for new HT connections and transformer centres under MSEDCL in Kolhapur.
What is a LBSF One I/C & Multiple O/G Panel?
This segment is useful where 2 or 3 distribution transformers are located in one place. A single cable can be laid for the whole setup, saving costs by up to 40%. A breaker can be installed before this unit as per the I.E. rules and coupled to the panel through an adaptor panel.
How many transformers can one I/C & multiple O/G panel feed?
It is typically built for 2 or 3 distribution transformers at one location, all fed through a single incoming cable.
Is the LBSF One I/C & Multiple O/G Panel suitable for heavy monsoon rain in Kolhapur?
Yes. The heavy steel sheet enclosure protects the mechanism from rain, dust and insects, which matters during Kolhapur's heavy monsoon.
How do I get a quotation for the LBSF One I/C & Multiple O/G Panel in Kolhapur?
Call +91 98220 21564, email response@eltechcontrols.com or fill in the enquiry form with your transformer rating, number of transformers and site location in Kolhapur.
Areas We Serve in Kolhapur
- Shiroli MIDC
- Gokul Shirgaon MIDC
- Kagal MIDC
- Ichalkaranji
- Jaysingpur
- Hatkanangale
- Gadhinglaj
- Panhala
Why EL-Tech Controls
- Over two decades of LBSF panel manufacturing
- Easy and smooth operation, no overhead lines
- Fully enclosed, electrically safe cubicle
- Safety interlocks allow semi-skilled operation
- Less space and low maintenance cost
- Direct manufacturer supply to Kolhapur
Contact for Kolhapur Enquiries
+91 98220 21564
+91 253 2383478 / 2380076
response@eltechcontrols.com
A-9/4/3, MIDC, Ambad, Nashik 422010
Need a LBSF One I/C & Multiple O/G Panel in Kolhapur?
Share your transformer rating, quantity and site location for a quick quotation.
Send EnquiryOther Products in Kolhapur
- 12 KV LBSF Panel in Kolhapur
- LBSF Coupled Type in Kolhapur
- Feeder Pillar Type in Kolhapur
- Feeder Pillar + Coupled in Kolhapur
- LBS Isolator Panel in Kolhapur
- Compact Substation in Kolhapur
- Panel Cleaning Solutions in Kolhapur
LBSF One I/C & Multiple O/G Panel in Nearby Cities
See full product details on our 12 KV LBSF Panel - One I/C & Multiple O/G page, or view all locations we serve.